• Users Online: 344
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 9  |  Issue : 2  |  Page : 90-93

Evaluation and comparison of tensile bond strength of addition silicone impression material with different tray adhesives


1 Department of Prosthodontics and Crown and Bridge, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Pune, Maharashtra, India
2 Department of Prosthodontics and Crown and Bridge, Sree Balaji Dental College and Hospitals, Chennai, Tamil Nadu, India

Correspondence Address:
Dr. Vasantha Vijayaraghavan
Department of Prosthodontics and Crown and Bridge, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Pune, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijmd.ijmd_47_19

Rights and Permissions

Statement of Problem: Very few studies have been conducted on the comparative evaluation of bond strength of elastomeric impression material to custom tray material using two different universal adhesive systems. Materials and Methods: A special mold was made for the fabrications of 24 samples of tray resin materials. They were divided into two main groups of 12. Perforations followed by adhesive application were done according to the grouping of samples. Polyvinyl siloxane material (medium body) was placed over the samples. A universal testing machine with a crosshead speed of 5 mm/min was used to determine the tensile bond strength of tray resin samples to medium body impression material by using different universal adhesives. Based on these values, Student's “t” test, group statistics, and ANOVA test were applied. Results: By using analysis of variance, there was no significant difference between the strength of bonding of tray resin material and medium body addition silicone by different adhesive systems. Conclusion: It was concluded that Medicept Universal tray adhesive system is as good as 3M™ universal tray adhesive system to achieve a good bond between tray resin and medium body addition silicone.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6889    
    Printed662    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal